Urology
Renal Surgery
Urologists performing robotic or laparoscopic renal surgery appreciate the many benefits provided by VTI’s 8 MHz Drop-In Doppler probe. Surgeons choose VTI’s Drop-In Doppler to guide dissection & isolation of the renal hilum and aberrant vasculature during these complex procedures. With over 25% of patients presenting with variations in their renal vascular anatomy, the VTI Drop-In Doppler probe provides a SOUND SOLUTION to the challenges of robotic renal surgery.
During robotic surgery, the Drop-In Doppler is placed into the operative field through the assistant port. It can then be manipulated by the console surgeon via the robotic instruments. Unlike intraoperative ultrasound, the VTI flexible Drop-In Doppler fits into small spaces and provides precise, pinpoint localization of the vasculature. It is ideally suited for facilitating hilar dissection and for confirming ischemia after clamping.
Surgical Procedures
- Robotic or laparoscopic partial nephrectomy
- Robotic or laparoscopic radical nephrectomy
- Robotic or laparoscopic pyeloplasty
Doppler Uses
- Facilitates dissection of the renal hilum, especially in cases with significant overlying fat/scarred tissue
- Facilitates identification of aberrant vasculature, including duplicated vessels and early branching
- Confirms adequate ischemia after clamping
- Facilitates identification of crossing vessels in pyeloplasty
Clinical Studies Demonstrate:
Use of Doppler probe during minimally invasive partial nephrectomy:
- Minimizes risk of significant bleeding1
- Leads to a change in operative management2
- Significantly reduces hilar dissection time1
Use of Doppler during minimally invasive renal surgery provides fast, efficient identification of the renal hilum without an added learning curve3
References:
1 Mues AC, Okhunov Z, Badani K, Gupta M, Landman J. “Intraoperative evaluation of renal blood flow during laparoscopic partial nephrectomy with a novel Doppler system.” J Endourol. 2010 Dec;24(12):1953-6.
2 Hyams ES, Perlmutter M, Stifelman MD. “A prospective evaluation of the utility of laparoscopic Doppler technology during minimally invasive partial nephrectomy.” Urology. 2011 Mar;77(3):617-20.
3 Sethi AS, Regan SM, Sundaram CP. “The use of a Doppler ultrasound probe during vascular dissection in laparoscopic renal surgery.” J Endourol. 2009 Sep;23(9):1377-82.
Catalog Details
Product Name | Box Quantity | Product Number |
---|---|---|
VTI SURGICAL DOPPLER 8MHz, AC POWER | 1 | 108910-AC |
VTI 8 MHz SURGICAL DOPPLER TRANSCEIVER SELECTABLE CHANNEL, (DC POWER) | 1 | 108910 |
VTI DOPPLER PROBE, STERILE, 8MHz, (ROBOTIC DROP IN, 2.3mm TIP) | 4 | 108370 |
POWER SUPPLY: DESKTOP 90-264 VAC | 1 | 108110-Supply |
POWER CORD: HOSPITAL US | 1 | 108110-US |
Other Specialties
Reconstructive
VTI’s TQI Doppler System provides a reliable and cost-effective solution for locating perforators and evaluating anastomoses in free flap surgeries.
GI Endoscopy
VTI’s Selectable Depth Doppler System is a sound breakthrough in the endoscopic treatment of acute peptic ulcer hemorrhage; its use can reduce rebleed rates.